  Datasheet File OCR Text:
  condor d.c. power supplies, inc., a subsidiary of sl industries, inc. 805-486-4565 ?(800) 235-5929 fax: (805) 487-8911 http://www.condorpower.com 1200 watts power factor corrected single output, hot swap model output rating pwr out SPH-1200-24 24v @ 50a 1200 SPH-1200-28 28v @ 42a 1200 SPH-1200-48 48v @ 25a 1200 standard sph series the SPH-1200 series provides low- cost, highly reliable, n+1 redundant hot swap power for critical applications. these 1200-watt single-output power supplies include an integral fan and are available with a front panel and handle for front access in sub-system racks or without handles for embedded applications. power factor correction, or-ing diodes, and current sharing make the sph series an ideal choice for communi- cations and data processing systems utilizing distributed power or redundant power architecture. SPH-1200 featuring: diode isolated output for hot swap ?ero wire?slope program current sharing for redundancy high power density: 5 w/cu. in. industry standard din connector universal ac input 0.99 typical power factor dc power good and ac power fail signals true remote inhibit monotonic turn-on and turn-off see trs (rack system)
condor d.c. power supplies, inc., a subsidiary of sl industries, inc. 805-486-4565 ?(800) 235-5929 fax: (805) 487-8911 http://www.condorpower.com specifications: all models input ac input: 105-264 vac continuous range, 47 to 63 hz. internally fused for 20 a. power factor: 0.99 typical at full load. meets en61000-3-2. inrush: cold start ac current is less than 75 a at 115 vac and 150 a at 230 vac for 8 ms typical. limited by thermistor. holdup time: 16 ms minimum after removal of power at full load. efficiency: 80% minimum ac power fail: provides ttl ?? 5 ms before output voltage goes out of regulation band upon loss of ac power. brownout protection: holds regulation to 85 vac for 30 seconds maximum. output adjustability: user adjustable ?% minimum. line regulation: ?.2% load regulation: ?% (slope program) from 0 to 100% load change. turn on delay: 1 second typical output rise time: (from 10% to 90%) 20 ms typical. ripple & noise: less than 1% p-p, measured at 20 mhz bandwidth. temperature coefficient: 0.02% per degree c. stability: 0.1% over 8 hours after 30 minutes warm-up. transient response: output voltage returns to within 1% in less than 500 ? for a 50% load change. peak transient does not exceed 3%. overload protection: electronic current limit, 120% maximum. overvoltage protection: protects load against power supply induced overvoltage. trip point is factory set so that output voltage cannot exceed 136% of nominal. requires ac input to be cycled to reset. remote inhibit: contact closure or a ttl level ??turns off dc output. dc power good: provides a ttl ??open collector when output is above 90% of nominal. maximum pull-up voltage 30 vdc; maximum sink current, 10 ma. redundancy: built-in or-ing diode, slope program current sharing, and din blade connector provide ?ot swap?and ?+1?capabilities. current sharing remains within 10% of the units full output rating given 0.2% initial accuracy in the output voltage setting. status indicators: green led on the front panel indicates normal operation (acpf high and dcpg low) environmental thermal protection: shuts down power supply if overheated. automatic recovery. temperature range: 0 to 50? at full ratings. safety agencies: approved to ul1950; csa 22.2 #950; iec 950 and t?v en60950, class 1 selv, ce 73/23/eec//93/68/eec (low voltage directive). conducted rfi: meets fcc part 15, subpart j, class a; en55022 class b; and cispr 22 class b. cooling: self-cooled by internal ball-bearing fan. 1200 watts 13.44? 5? 4.03 SPH-1200 function location notes connector output z12 d14 z16 d18 (+) to polarity voltage z4 d6 z8 d10 (-) to polarity function location notes connector dc power good z20 reference to ac power fail d22 to common inhibit z24 location 115 vac 230 vac connector z32 line line 1 d30 neutral line 2 see below z28 safety ground safety ground ac input (105-264 vac continuous range) dc output eurocard connector - male din 41 612 level 1- type h status and control see above options option ?? rack mount panel: special panel is required for rack mounting. consult factory for other available options. dimensions: inches millimeters SPH-1200 7.3 lbs - 3.3 kgs


▲Up To Search▲   

 
Price & Availability of SPH-1200

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X